Forensic Identification of Human Blood: comparison of two one-step presumptive tests for blood screening of crime scene samples.

Ana Flávia Belchior Andrade, Maria Emília Cambria Guimaro Siqueira, Luciano Chaves Arantes, Larissa Silva Queiroz, Rayane Luiza Viegas Silva, Eduardo Dias Ramalho

Resumo


Blood is the most common body fluid found at crime scenes. One-step presumptive tests have been designed as a rapid immunological test for the qualitative detection of human hemoglobin in stool samples (faecal occult blood) their usefulness for forensic purposes has been demonstrated before. In this study we compare Hexagon OBTI kit and FOB One-step Bioeasy kit sensitivity in the analysis of diluted blood samples. With Hexagon OBTI, positive test results are achieved in whole blood dilutions up to 1:1.000. Sensitivity decreased with aged samples, if samples were not stored under low temperatures regardless of which presumptive test is used. Whole blood tests must take into consideration that “hook” effect may interfere. Comparing both tests, OBTI Hexagon Kit is more sensible to detect diluted blood, showing a wider detection window in all conditions. This is interesting when analyzing forensic samples as forensic analysts usually do not know about the history of the analyzed sample before its collection.


Palavras-chave


Sangue; Teste Presuntivo; Hexagon OBTI

Texto completo:

PDF

Referências


J. H. An, K.-J. Shin, W. I. Yang, K. Y. Lee, "Body fluid identification in forensics", BMB Reports 45(10): 545-553, 2012.

Human Diagnostic Worldwide, “Design verification and product data for Hexagon OBTI”. Rev. 012, 2012.

M. N. Hochmeister, B. Budowle, R. Sparkes, O. Rudin, C. Gehrig, M. Thali, L. Schmidt, A. Cordier, R. Dirnhofer, “Validation studies of immunochromatographic 1-step test for the identification of human blood”. J. Forensic Sci. 44(3): 597-602, 1993.

D. Hemon, M. Shpitzen, C. Oz, B. Glattstein, M. Aroury, R. Gafny, “The use of Hexagon OBTI test for detection of human blood at crime scene and on itens of evidence part I: Validation studies and implementation”. J. Forensic Identif. 53(5): 566-575, 2003.

E. Johnston, C. E. Ames, K. E. Dagnall, J. Foster, B. E. Daniel, “Comparative of presumptive blood test kits including Hexagon OBTI”. J. Forensic Sci. 53(3): 687-689, 2008.

S. A. Fernando, G. S. Wilson, “Studies of “hook” effect in one-step sandwich immunoassay”. J. Immunological Methods, 151: 47-66, 1992.

P. Longo, C. R. Dias Filho, M. P. O. Valadares, E. C. Alonso, S. P. S. Gonçalves, E. Auler-Bittencourt. “Avaliação comparativa de teste imunocromatográfico para identificação forense de sangue humano”. R. Bras. Criminalística, 1:1-16-21, 2011.




DOI: http://dx.doi.org/10.15260/rbc.v3i1.68

Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.